Skip Nav Destination
Close Modal
Update search
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
NARROW
Format
Article Type
Subject Area
Topics
Date
Availability
1-20 of 38
Keywords: blood vessels
Close
Follow your search
Access your saved searches in your account
Would you like to receive an alert when new items match your search?
1
Sort by
Journal Articles
Brandon J. Hopkins, Huayin Wu, William H. Marks, Qimin Quan, Samuel Kesner, C. Keith Ozaki, Conor Walsh
Journal:
Journal of Medical Devices
Article Type: Research Papers
J. Med. Devices. June 2012, 6(2): 021011.
Published Online: May 7, 2012
.... , 1 , p. 9000102 . 10.1109/LMAG.2010.2081351 04 11 2011 20 02 2012 07 05 2012 07 05 2012 blood blood vessels kidney patient treatment graft Up to eight percent of patients undergoing permanent hemodialysis (HD) access placement develop steal syndrome [( 1...
Journal Articles
Journal:
Journal of Medical Devices
Article Type: Research Papers
J. Med. Devices. December 2011, 5(4): 041002.
Published Online: November 7, 2011
... – 1364 . 10.1016/S0002-9149(02)02347-0 17 10 2010 24 09 2011 07 11 2011 07 11 2011 blood vessels cardiovascular system haemodynamics medical computing mesh generation physiological models Poisson ratio stents stress-strain relations A cardiovascular...
Journal Articles
Megha Agrawal, Vaibhavi A. Sonetha, Smriti Sharma, Satyajeet Parakh, Bharat Dalvi, Jayesh R. Bellare
Journal:
Journal of Medical Devices
Article Type: Design Innovations
J. Med. Devices. September 2011, 5(3): 035001.
Published Online: August 30, 2011
... serve as a simplistic and cost effective alternative for PDA occlusion. 15 04 2010 07 10 2010 30 08 2011 30 08 2011 adhesion biomechanics biomedical electronics biomedical equipment biomedical imaging blood blood vessels cardiology cellular biophysics diseases ducts...
Journal Articles
Journal:
Journal of Medical Devices
Article Type: Design Of Medical Devices Conference Abstracts
J. Med. Devices. June 2011, 5(2): 027539.
Published Online: June 15, 2011
...Stephen Howard; Cory Kasprzak; Chris Rolfes; Paul A. Iaizzo 15 06 2011 15 06 2011 biomechanics biomedical materials blood vessels cardiovascular system catheters surgery Clinical access to the left atrium and/or to the left ventricle for medical device delivery, from...
Journal Articles
Journal:
Journal of Medical Devices
Article Type: Design Of Medical Devices Conference Abstracts
J. Med. Devices. June 2011, 5(2): 027534.
Published Online: June 14, 2011
...Scott A. Skorupa; Julianne H. Eggum; Paul A. Iaizzo 14 06 2011 14 06 2011 blood vessels cardiovascular system diagnostic radiography haemorheology image reconstruction medical image processing physiological models It is important to identify and understand variations...
Journal Articles
Journal:
Journal of Medical Devices
Article Type: Design Of Medical Devices Conference Abstracts
J. Med. Devices. June 2011, 5(2): 027521.
Published Online: June 13, 2011
...Shijia Zhao; Xiangyi Liu; Linxia Gu 13 06 2011 13 06 2011 biomechanics biomedical materials blood vessels finite element analysis stents Interwoven self-expandable stents demonstrate distinct characteristics compared with laser-cut ones. In this study, the deployment...
Journal Articles
Journal:
Journal of Medical Devices
Article Type: Design Of Medical Devices Conference Abstracts
J. Med. Devices. June 2011, 5(2): 027507.
Published Online: June 9, 2011
...Ying Han; Linxia Gu 09 06 2011 09 06 2011 blood vessels cardiovascular system haemodynamics physiological models Arterial coarctation especially that occurs in aorta is an extremely significant health problem. Though it is a result of numerous factors, hemodynamics...
Journal Articles
Journal:
Journal of Medical Devices
Article Type: Design Of Medical Devices Conference Abstracts
J. Med. Devices. June 2011, 5(2): 027505.
Published Online: June 9, 2011
...Polina A. Segalova; Guanglei Xiong; K. T. Rao; Christopher K. Zarins; Charles A. Taylor 09 06 2011 09 06 2011 blood vessels computational fluid dynamics computerised tomography diagnostic radiography haemodynamics medical disorders prosthetics Computer modeling...
Journal Articles
Journal:
Journal of Medical Devices
Article Type: Research Papers
J. Med. Devices. June 2011, 5(2): 021002.
Published Online: May 2, 2011
..., it is important to avoid accidental injury to surrounding tissues and blood vessels since, were this to occur, it could then necessitate the need to resort to open surgery. The present study is aimed at developing a three-dimensional tactile display that provides palpation capability to any surgeon performing...
Journal Articles
Journal:
Journal of Medical Devices
Article Type: Research Papers
J. Med. Devices. December 2010, 4(4): 041007.
Published Online: December 6, 2010
... biomedical materials blood vessels deformation polymers stents scission hydrolysis degradation damage strain-softening PLLA Fully biodegradable polymeric stents are thought to be the third revolution in minimally invasive cardiology. After the breakthrough development of percutaneous...
Journal Articles
Journal:
Journal of Medical Devices
Article Type: Design Innovations
J. Med. Devices. December 2010, 4(4): 045004.
Published Online: December 3, 2010
... by Analysis From Reflected Ultrasound Echoes—A Review ,” IEEE Trans. Ultrason. Ferroelectr. Freq. Control 0885-3010 , 40 ( 2 ), pp. 84 – 102 . 10.1109/58.212556 19 02 2010 17 08 2010 03 12 2010 03 12 2010 biomedical ultrasonics blood vessels cardiovascular system...
Journal Articles
Journal:
Journal of Medical Devices
Article Type: Research Papers
J. Med. Devices. September 2010, 4(3): 031005.
Published Online: August 31, 2010
... 08 2010 31 08 2010 biomechanics biomedical measurement blood vessels cardiovascular system finite element analysis stents restenosis stent plaque artery interface correlation finite element method In the United States, 1.2 million patients undergo stent...
Journal Articles
Journal:
Journal of Medical Devices
Article Type: Design Of Medical Devices Conference Abstracts
J. Med. Devices. June 2010, 4(2): 027541.
Published Online: August 12, 2010
... in surgical robotic devices. 12 08 2010 actuators blood vessels cardiovascular system endoscopes medical robotics surgery 2010 American Society of Mechanical Engineers ...
Journal Articles
Journal:
Journal of Medical Devices
Article Type: Design Of Medical Devices Conference Abstracts
J. Med. Devices. June 2010, 4(2): 027534.
Published Online: August 11, 2010
... was then fabricated for these subjects based on the outcome of the simulations. In this paper, we explain how a computer aided subject-specific design was used to help fabricate and test our sensor. 11 08 2010 biomedical MRI biosensors blood vessels brain CAD diseases finite element analysis...
Journal Articles
Journal:
Journal of Medical Devices
Article Type: Design Of Medical Devices Conference Abstracts
J. Med. Devices. June 2010, 4(2): 027530.
Published Online: August 11, 2010
... biomedical equipment biothermics blood vessels cardiology haemorheology molecular biophysics 2010 American Society of Mechanical Engineers ...
Journal Articles
Davide Dal Pozzo, Martin Deterre, Damien Eggenspieler, Maxim Lobovsky, Frank Pigula, Alexander H. Slocum
Journal:
Journal of Medical Devices
Article Type: Design Of Medical Devices Conference Abstracts
J. Med. Devices. June 2010, 4(2): 027526.
Published Online: August 10, 2010
... be started. 10 08 2010 biomechanics biomedical engineering biomedical equipment blood vessels hydraulic actuators paediatrics 2010 American Society of Mechanical Engineers ...
Journal Articles
Journal:
Journal of Medical Devices
Article Type: Design Of Medical Devices Conference Abstracts
J. Med. Devices. June 2010, 4(2): 027523.
Published Online: August 10, 2010
... intraluminal images, we achieve a detailed assessment of the diameter and wall thickness of the inflated balloon at different pressures. Such analysis is helpful in testing the balloon quality, in assessing deformation model, or in validating new balloon designs. balloons blood vessels deformation...
Journal Articles
Journal:
Journal of Medical Devices
Article Type: Design Of Medical Devices Conference Abstracts
J. Med. Devices. June 2010, 4(2): 027504.
Published Online: August 9, 2010
.... 09 08 2010 09 08 2010 blood blood flow measurement blood vessels cardiovascular system computational fluid dynamics diseases haemodynamics haemorheology hydrodynamics kidney mesh generation physiological models 2010 American Society of Mechanical Engineers ...
Journal Articles
Journal:
Journal of Medical Devices
Article Type: Design Of Medical Devices Conference Abstracts
J. Med. Devices. June 2009, 3(2): 027554.
Published Online: July 24, 2009
... wireless transmission (250 Kbps), SpO2 and pulse signals can be processed on a PC or operating room VI. The incorporation of a pressure sensor to increase accuracy and robustness is explored. The device was validated intra-operatively on rodent and bovine surgical models. biosensors blood vessels...
Journal Articles
Journal:
Journal of Medical Devices
Article Type: Design Of Medical Devices Conference Abstracts
J. Med. Devices. June 2009, 3(2): 027525.
Published Online: July 9, 2009
... area for platelet deposition. Therefore, increasing strut size has a threefold effect on platelet deposition rate, leading to faster vessel occlusion. This computational technique may be extended to approximate where thrombus may grow to completely occlude a blood vessel and the length of time...
1