Abstract

After a median sternotomy, the sternum has to be refixated using implants such as wires, plates, or clamps. However, there is still a lack of specifically applicable test methods to investigate the mechanical safety and effectiveness of such implant systems. The aim of this study was to develop a new test method that replicates the in vivo loads acting on the sternum and that is applicable to all types of sternal closure systems. Based on the scientific literature, a setup was developed that incorporates the physiological loads acting on the sternum during breathing (91 N) and coughing (328 N). These loads are applied to a sternum replicate at 5 Hz for approximately 1.8 × 106 cycles. This cycle number is assumed to represent the healing period. For validation, the new method was applied to two different sternal closure systems: a PEEK clamp system and wires. The new test method proved to be easily applicable. The validation tests with the two sternal closure systems showed reasonable and reproducible results regarding all outcome parameters. The pretension exerted by the implants significantly differed between the two implant groups and decreased after the first coughing cycles. The fracture gap separation during breathing also significantly different between the two test groups, but it was similar during coughing. No implant failed. Using this new test method, it is possible to compare sternal closure systems under reproducible, in vivo-based conditions and interpret their mechanical characteristics regarding their clinical safety and effectiveness.

References

1.
Alhalawani
,
A. M. F.
, and
Towler
,
M. R.
,
2013
, “
A Review of Sternal Closure Techniques
,”
J. Biomater. Appl.
,
28
(
4
), pp.
483
497
.10.1177/0885328213495426
2.
Losanoff
,
J. E.
,
Collier
,
A. D.
,
Wagner-Mann
,
C. C.
,
Richman
,
B. W.
,
Huff
,
H.
,
Hsieh
,
F.
,
Diaz-Arias
,
A.
, and
Jones
,
J. W.
,
2004
, “
Biomechanical Comparison of Median Sternotomy Closures
,”
Ann. Thorac. Surg.
,
77
(
1
), pp.
203
209
.10.1016/S0003-4975(03)01468-1
3.
Ozaki
,
W.
,
Buchman
,
S. R.
,
Iannettoni
,
M. D.
, and
Frankenburg
,
E. P.
,
1998
, “
Biomechanical Study of Sternal Closure Using Rigid Fixation Techniques in Human Cadavers
,”
Ann. Thorac. Surg.
,
65
(
6
), pp.
1660
1665
.10.1016/S0003-4975(98)00231-8
4.
Wangsgard
,
C.
,
Cohen
,
D. J.
, and
Griffin
,
L. V.
,
2008
, “
Fatigue Testing of Three Peristernal Median Sternotomy Closure Techniques
,”
J. Cardiothorac. Surg.
,
3
(
1
), p.
52
.10.1186/1749-8090-3-52
5.
Schimmer
,
C.
,
Reents
,
W.
, and
Elert
,
O.
,
2006
, “
Primary Closure of Median Sternotomy: A Survey of All German Surgical Heart Centers and a Review of the Literature Concerning Sternal Closure Technique
,”
J. Thorac. Cardiovasc. Surg.
,
54
(
6
), pp.
408
413
.10.1055/s-2006-924193
6.
ASTM
,
2017
,
Specification for Metallic Implantable Strands and Cables
, ASTM International, West Conshohocken, PA,
Standard No. ASTM F2180-17.
7.
ASTM
,
2017
,
Specification and Test Method for Metallic Bone Plates
, ASTM International, West Conshohocken, PA,
Standard No. ASTM F382-17.
8.
Dasika
,
U. K.
,
Trumble
,
D. R.
, and
Magovern
,
J. A.
,
2003
, “
Lower Sternal Reinforcement Improves the Stability of Sternal Closure
,”
Ann. Thorac. Surg.
,
75
(
5
), pp.
1618
1621
.10.1016/S0003-4975(02)04988-3
9.
Sant
,
Z.
,
Casha
,
A. R.
, and
Cilia
,
J.
,
2011
, “
Can the Foam Model Simulate the Bone Behaviour?
,”
17th International Conference, Engineering Mechanics
, Svratka, Czech Republic, May 9–12, pp.
527
530
.https://www.um.edu.mt/library/oar/handle/123456789/27034
10.
Adams
,
J.
,
Schmid
,
J.
,
Parker
,
R. D.
,
Coast
,
J. R.
,
Cheng
,
D.
,
Killian
,
A. D.
,
McCray
,
S.
,
Strauss
,
D.
,
McLeroy Dejong
,
S.
, and
Berbarie
,
R.
,
2014
, “
Comparison of Force Exerted on the Sternum During a Sneeze Versus During Low-, Moderate-, and High-Intensity Bench Press Resistance Exercise With and Without the Valsalva Maneuver in Healthy Volunteers
,”
Am. J. Cardiol.
,
113
(
6
), pp.
1045
1048
.10.1016/j.amjcard.2013.11.064
11.
Casha
,
A. R.
,
Yang
,
L.
,
Kay
,
P. H.
,
Saleh
,
M.
, and
Cooper
,
G. J.
,
1999
, “
A Biomechanical Study of Median Sternotomy Closure Techniques
,”
Eur. J. Cardio-Thorac. Surg.
,
15
(
3
), pp.
365
369
.10.1016/S1010-7940(99)00014-7
12.
Parker
,
R.
,
Adams
,
J. L.
,
Ogola
,
G.
,
McBrayer
,
D.
,
Hubbard
,
J. M.
,
McCullough
,
T. L.
,
Hartman
,
J. M.
, and
Cleveland
,
T.
,
2008
, “
Current Activity Guidelines for CABG Patients Are Too Restrictive: Comparison of the Forces Exerted on the Median Sternotomy During a Cough Vs. Lifting Activities Combined With Valsalva Maneuver
,”
J. Thorac. Cardiovasc. Surg.
,
56
(
4
), pp.
190
194
.10.1055/s-2008-1038470
13.
Pai
,
S.
,
Dunn
,
R. M.
,
Babbitt
,
R.
,
Strom
,
H. M.
,
Lalikos
,
J. F.
,
Pins
,
G. D.
, and
Billiar
,
K. L.
,
2008
, “
Characterization of Forces on the Sternal Midline Following Median Sternotomy in a Porcine Model
,”
ASME J. Biomech. Eng.
,
130
(
5
), p.
51004
.10.1115/1.2948401
14.
Yousaf
,
N.
,
Monteiro
,
W.
,
Matos
,
S.
,
Birring
,
S. S.
, and
Pavord
,
I. D.
,
2013
, “
Cough Frequency in Health and Disease
,”
Eur. Respir. J.
,
41
(
1
), pp.
241
243
.10.1183/09031936.00089312
15.
McGregor
,
W. E.
,
Trumble
,
D. R.
, and
Magovern
,
J. A.
,
1999
, “
Mechanical Analysis of Midline Sternotomy Wound Closure
,”
J. Thorac. Cardiovasc. Surg.
,
117
(
6
), pp.
1144
1150
.10.1016/S0022-5223(99)70251-5
16.
Cohen
,
C. D. J.
, and
Griffin
,
L. V.
,
2002
, “
A Biomechanical Comparison of Three Sternotomy Closure Techniques
,”
Ann. Thorac. Surg.
,
73
(
2
), pp.
563
568
.10.1016/S0003-4975(01)03389-6
17.
Pai
,
S.
,
Gunja
,
N. J.
,
Dupak
,
E. L.
,
McMahon
,
N. L.
,
Roth
,
T. P.
,
Lalikos
,
J. F.
,
Dunn
,
R. M.
,
Francalancia
,
N.
,
Pins
,
G. D.
, and
Billiar
,
K. L.
,
2005
, “
In Vitro Comparison of Wire and Plate Fixation for Midline Sternotomies
,”
Ann. Thorac. Surg.
,
80
(
3
), pp.
962
968
.10.1016/j.athoracsur.2005.03.089
18.
Baril
,
Y.
,
Brailovski
,
V.
,
Chartrand
,
M.
,
Terriault
,
P.
, and
Cartier
,
R.
,
2009
, “
Median Sternotomy: Comparative Testing of Braided Superelastic and Monofilament Stainless Steel Sternal Sutures
,”
Proc. Inst. Mech. Eng. Part H J. Eng. Med.
,
223
(
3
), pp.
363
374
.10.1243/09544119JEIM481
19.
Zeitani
,
J.
,
Penta de Peppo
,
A.
,
Bianco
,
A.
,
Nanni
,
F.
,
Scafuri
,
A.
,
Bertoldo
,
F.
,
Salvati
,
A.
,
Nardella
,
S.
, and
Chiariello
,
L.
,
2008
, “
Performance of a Novel Sternal Synthesis Device After Median and Faulty Sternotomy: Mechanical Test and Early Clinical Experience
,”
Ann. Thorac. Surg.
,
85
(
1
), pp.
287
293
.10.1016/j.athoracsur.2007.08.036
20.
Behanzin
,
A. V.
,
Dellasanta
,
B. L.
, and
Pizzimenti
,
C. A.
,
2013
,
Design of a Sternal Fixation Device and Bicortical Bone Model
,
Bachelorarbeit
,
Worcester Polytechnic Institute
, Worcester, MA.
21.
Trumble
,
D. R.
,
McGregor
,
W. E.
, and
Magovern
,
J. A.
,
2002
, “
Validation of a Bone Analog Model for Studies of Sternal Closure
,”
Ann. Thorac. Surg.
,
74
(
3
), pp.
739
744
.10.1016/S0003-4975(02)03699-8
22.
Claes
,
L.
,
Wolf
,
S.
, and
Augat
,
P.
,
2000
, “
Mechanische Einflüsse Auf Die Callusheilung
,”
Der Chirurg; Z. Alle Gebiete Operat. Medizen
,
71
(
9
), pp.
989
994
.10.1007/s001040051172
You do not currently have access to this content.