An analytical model to predict two-phase critical flow rate is proposed. The model is based upon thermal equilibrium, a “lumped” treatment of the two-phase velocity (each phase is represented by a single mean velocity), and upon the neglect of frictional and hydrostatic pressure losses. A comparison of the proposed predictions with available test results and previous analyses shows that: (a) The present model agrees very well with the published test data; (b) In contrast to all other analyses, the model requires no assumption about the gas void fraction.