A managed program to review engine failures and take necessary preventative measures has been in place successfully in the Royal Navy since the introduction of gas turbines into service in the 1970s. One of the more prominent failure mechanisms with the Tyne RM1C and Spey SM1A engines has been the degradation of main line bearings accounting for 25% of all engines rejected. Historically, since the first recorded incident in March 1987, the failures pointed to poor performance of the bearings themselves. However, maintenance studies and recent analysis indicates that a vast proportion have occurred through previously unidentified chloride corrosion as a result of contamination of the lubricating oil system with salt water from the seawater lubricating oil cooler (SWLO cooler). Despite joint ownership of both engine variants with the Royal Netherlands Navy, there was no clear evidence until about five years ago to suggest why tube perforation was occurring. Indeed, the fact that failures have only occurred in Royal Navy service is an interesting twist to the problem. This paper summarizes the phenomenon of SWLO cooler corrosion caused by Microbial Induced Corrosion (principally Sulphate Reducing Bacteria—SRB). It highlights the conditions in which SRB occurs along with demonstrated prevention in Royal Navy gas turbine service through the combined efforts of maintenance and development of a new titanium tubestack. The fault finding and remedial recovery experience may well be of interest to operators of marine gas turbines, both naval and commercial, who use tube type heat exchangers, especially when operating or undertaking work in estuarial waters and nontidal basins or when undertaking littoral duties. This is a practical view of the issue from an operators perspective and while utilizing a wealth of research and technical data available on the subject, it relates the issues at hand to the particular corrosion problem and is not intended as an introduction into organic chemistry.

1.
Factors Affecting the Corrosion and Fouling of Metal Condenser Tubes of Copper Alloys and Titanium
,” 1978, Sumitomo Light Metal Technical Reports. Vol
19
, Nos. 3/4.
2.
Peacock
,
D. K.
, 1998, “
Effective Design of Marine High Performance Corrosion Resistant Systems Using Titanium
,”
TransIMarE
,
110
, Pt. 3, pp.
155
170
.
3.
Price
,
R.
, 2000, “
Investigation into Failures of Tyne and Spey Lubricating Oil Coolers
,” Unpublished UK MoD Report, Apr. 27.
4.
British Standards Institute, 1973, “
Code of Practice for Salt Water Piping Systems in Ships (Obsolete)
,” British Standard BS MA18.
5.
McCann
,
A. J.
, 1998, “
Failure Investigation into HMS Cumberland Tyne and Spey GT Sea Water Lub Oil Coolers
,” Unpublished UK MoD report, Feb. 13.
6.
Mistry
,
A. J.
, 1992, HMS Argyll Cooler Failure Investigation, Spey Development Technical Report SDTR 232, Mar. 24.
7.
Powell
,
Carol A.
, 1992, “
CuNi Alloys-Resistance to Corrosion and Biofouling
,” Copper Development Association Seminar Technical Report 7044-1919.
8.
Tuthill
,
A. H.
, 1987,
Guidelines for the Use of Copper Alloys in Seawater
, Copper Development Association, Materials Performance Manual, pp.
155
170
.
9.
Defect Acquaint Form S/No. 4528\1, 2001, unpublished UK MoD S2022a (1998 original revised and updated).
10.
“Titanium for Offshore and Marine Applications,” 1999,
A Designers and Users handbook
,
Titanium Information Group
, 2nd ed.
11.
Todd
,
B.
, and
Lovett
,
P. A.
, 2000,
Selecting Materials for Sea Water Systems
,
Marine Engineers
Practice, 2, Pt. 10, June.
12.
Jarman
,
S. E.
,
Winzar
,
J.
,
Chard-Tuckey
,
P. R.
,
Dickinson
,
P.
,
Heron
,
B.
,
Kilmartin
,
A.
, and
McGregor
,
C.
, 2003, “
An Electrochemical Performance Investigation of Polymetallic Seawater/Lube Oil Heat Exchangers Used in Spey and Tyne Gas Turbine Installations
,” unpublished UK MoD Report.
13.
Jarman
,
S. E.
, and
Chard-Tuckey
,
P. R.
, 2002, HMS Sultan Nuclear Department, In Service Inspection of Ti oil cooler fitted to HMS Edinburgh, unpublished UK MoD Report.
You do not currently have access to this content.