Skip Nav Destination
Close Modal
Update search
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
NARROW
Format
Article Type
Subject Area
Topics
Date
Availability
1-8 of 8
Keywords: ultrasound
Close
Follow your search
Access your saved searches in your account
Would you like to receive an alert when new items match your search?
Sort by
Journal Articles
Elnaz Ghajar-Rahimi, Diya D. Sakhrani, Radhika S. Kulkarni, Shiyin Lim, Blythe Dumerer, Annie Labine, Michael E. Abbott, Grace D. O'Connell, Craig J. Goergen
Journal:
Journal of Biomechanical Engineering
Publisher: ASME
Article Type: Technical Briefs
J Biomech Eng. March 2025, 147(3): 034501.
Paper No: BIO-24-1142
Published Online: January 17, 2025
... was to integrate high-frequency ultrasound and texture correlation to quantify disc strain during dynamic loading. We acquired ultrasound images of the posterior side of bovine discs in the transverse plane throughout 0–0.5 mm of assigned axial compression at 0.3–0.5 Hz. Internal Green-Lagrangian strains were...
Journal Articles
Journal:
Journal of Biomechanical Engineering
Publisher: ASME
Article Type: Research-Article
J Biomech Eng. March 2023, 145(3): 031003.
Paper No: BIO-22-1161
Published Online: December 5, 2022
... in asymptomatic hands. Twelve subjects were recruited to image the carpal tunnel using robot-assisted ultrasound. The median nerve and TCL were segmented from each image and three-dimensionally reconstructed using kinematic information from the robot. The TCL-median nerve distance, nerve cross-sectional area...
Journal Articles
Inputs for Subject-Specific Computational Fluid Dynamics Simulation of Blood Flow in the Mouse Aorta
Journal:
Journal of Biomechanical Engineering
Publisher: ASME
Article Type: Research-Article
J Biomech Eng. October 2014, 136(10): 101008.
Paper No: BIO-13-1535
Published Online: August 12, 2014
... , A. , Ruengsakulrach , P. , Lin , A. , Zhang , J. , Zhou , Y. Q. , Bishop , J. , Davidson , L. , Courtman , D. , Foster , F. S. , Steinman , D. A. , Henkelman , R. M. , and Ethier , C. R. , 2007 , “ Hemodynamics in the Mouse Aortic Arch as Assessed by MRI, Ultrasound...
Journal Articles
Journal:
Journal of Biomechanical Engineering
Publisher: ASME
Article Type: Technical Briefs
J Biomech Eng. July 2014, 136(7): 074504.
Paper No: BIO-13-1509
Published Online: May 29, 2014
... , “ Ultrasound Echo is Related to Stress and Strain in Tendon ,” J. Biomech. , 44 ( 3 ), pp. 424 – 429 . 10.1016/j.jbiomech.2010.09.033 [8] Duenwald-Kuehl , S. , Kobayashi , H. , Lakes , R. , and Vanderby , R. , 2012 , “ Time-Dependent Ultrasound Echo Changes Occur in Tendon During...
Journal Articles
Journal:
Journal of Biomechanical Engineering
Publisher: ASME
Article Type: Research Papers
J Biomech Eng. November 2012, 134(11): 111006.
Published Online: October 26, 2012
.... Our lab has previously presented acoustoelasticity as an alternative ultrasound-based method of measuring tendon stress and strain by reporting a relationship between ultrasonic echo intensity (B mode ultrasound image brightness) and mechanical behavior of tendon under pseudoelastic in vitro...
Journal Articles
Journal:
Journal of Biomechanical Engineering
Publisher: ASME
Article Type: Technical Papers
J Biomech Eng. June 2007, 129(3): 413–422.
Published Online: November 17, 2006
... phenomenon. PG is nonuniformly distributed throughout the depth direction, and its amount or distribution may change in the degenerated articular cartilage such as osteoarthritis. In this paper, we used a 50 MHz ultrasound system to study the depth-dependent strain of articular cartilage under the osmotic...
Journal Articles
Journal:
Journal of Biomechanical Engineering
Publisher: ASME
Article Type: Technical Papers
J Biomech Eng. June 2006, 128(3): 300–308.
Published Online: December 9, 2005
... the radiation force of focused amplitude-modulated ultrasound to exert a vibrating force directly, and remotely, on a bone. The vibration frequency is varied in the range of interest to induce resonances in the bone. The resulting bone motion is recorded and the resonance frequencies are determined. Experiments...
Journal Articles
Journal:
Journal of Biomechanical Engineering
Publisher: ASME
Article Type: Technical Papers
J Biomech Eng. December 2002, 124(6): 714–723.
Published Online: December 27, 2002
... 01 July 2002 27 12 2002 bone dentistry biomedical ultrasonics elastic moduli measurement biomedical measurement elastic constants ultrasonic velocity measurement biomechanics Ultrasound Mandible Femur Aluminum Human Studies of cortical bone elastic properties...