There are many causes of lengthening of an anterior cruciate ligament soft-tissue graft construct (i.e., ), which can lead to an increase in anterior laxity. These causes can be due to plastic deformation and∕or an increase in elastic deformation. The purposes of this in vitro study were (1) to develop the methods to quantify eight causes (four elastic and four plastic) associated with the tibial and femoral fixations using Roentgen stereophotogrammetric analysis (RSA) and to demonstrate the usefulness of these methods, (2) to assess how well an empirical relationship between an increase in length of the graft construct and an increase in anterior laxity predicts two causes (one elastic and one plastic) associated with the graft midsubstance, and (3) to determine the increase in anterior tare laxity (i.e., laxity under the application of a anterior tare force) before the graft force reaches zero. Markers were injected into the tibia, femur, and graft in six cadaveric legs whose knees were reconstructed with single-loop tibialis grafts. To satisfy the first objective, legs were subjected to at of anterior force transmitted at the knee. Based on marker 3D coordinates, equations were developed for determining eight causes associated with the fixations. After 1500 load cycles, plastic deformation between the graft and WasherLoc tibial fixation was the greatest cause with an average of followed by plastic deformation between the graft and cross-pin-type femoral fixation with an average of . The elastic deformations between the graft and tibial fixation and between the graft and femoral fixation decreased averages of and , respectively. The remaining four causes associated with the fixations were close to 0. To satisfy the remaining two objectives, after cyclic loading, the graft was lengthened incrementally while the anterior tare laxity, anterior laxity, and graft tension were measured. The one plastic cause and one elastic cause associated with the graft midsubstance were predicted by the empirical relationships with random errors (i.e., precision) of and , respectively. The minimum increase in anterior tare laxity before the graft force reached zero was . Hence, each of the eight causes of an increase in the anterior laxity associated with the fixations can be determined with RSA as long as the overall increase in the anterior tare laxity does not exceed . However, predicting the two causes associated with the graft using empirical relationships is prone to large errors.
Skip Nav Destination
e-mail: mlhull@ucdavis.edu
Article navigation
August 2008
Research Papers
Roentgen Stereophotogrammetric Analysis Methods for Determining Ten Causes of Lengthening of a Soft-Tissue Anterior Cruciate Ligament Graft Construct
Conrad Smith,
Conrad Smith
Biomedical Engineering Program,
University of California
, One Shields Avenue, Davis, CA 95616
Search for other works by this author on:
M. L. Hull,
M. L. Hull
Biomedical Engineering Program, and Department of Mechanical Engineering,
e-mail: mlhull@ucdavis.edu
University of California
, One Shields Avenue, Davis, CA 95616
Search for other works by this author on:
S. M. Howell
S. M. Howell
Department of Mechanical Engineering,
University of California
, One Shields Avenue, Davis, CA 95616
Search for other works by this author on:
Conrad Smith
Biomedical Engineering Program,
University of California
, One Shields Avenue, Davis, CA 95616
M. L. Hull
Biomedical Engineering Program, and Department of Mechanical Engineering,
University of California
, One Shields Avenue, Davis, CA 95616e-mail: mlhull@ucdavis.edu
S. M. Howell
Department of Mechanical Engineering,
University of California
, One Shields Avenue, Davis, CA 95616J Biomech Eng. Aug 2008, 130(4): 041002 (10 pages)
Published Online: May 16, 2008
Article history
Received:
January 16, 2007
Revised:
September 19, 2007
Published:
May 16, 2008
Citation
Smith, C., Hull, M. L., and Howell, S. M. (May 16, 2008). "Roentgen Stereophotogrammetric Analysis Methods for Determining Ten Causes of Lengthening of a Soft-Tissue Anterior Cruciate Ligament Graft Construct." ASME. J Biomech Eng. August 2008; 130(4): 041002. https://doi.org/10.1115/1.2904897
Download citation file:
Get Email Alerts
Cited By
Effect of Collagen Fiber Tortuosity Distribution on the Mechanical Response of Arterial Tissues
J Biomech Eng (February 2025)
Related Articles
Determination of Optimal Graft Lengths for Posterior Cruciate Ligament Reconstruction—A Theoretical Analysis
J Biomech Eng (April,2003)
Lengthening of a Single-Loop Tibialis Tendon Graft Construct After Cyclic Loading: A Study Using Roentgen Stereophotogrammetric Analysis
J Biomech Eng (June,2006)
Related Chapters
Basic Concepts
Design & Analysis of ASME Boiler and Pressure Vessel Components in the Creep Range
Analysis of the Affect of Heat Pipe Line Engineering Construction on the Settlement and Deformation Tunnels of Beijing Subway Line 10
Geological Engineering: Proceedings of the 1 st International Conference (ICGE 2007)
Study on Rock Mass Deformation Characteristics and Supporting Measures in Baozhen Tunnel
Geological Engineering: Proceedings of the 1 st International Conference (ICGE 2007)