Various graft materials have been used in posterior cruciate ligament (PCL) reconstruction. However, it is unclear if these grafts can reproduce the structural behavior of the PCL. This paper analyzed the effect of graft length on the structural behavior of the graft using a minimal deformation energy method. An analytical solution was obtained to determine the optimal effective graft length that can best reproduce the structural behavior of the PCL. This optimal graft length was determined as a function of the axial rigidity of the graft. Two typical grafts, bone-patella tendon-bone (BPTB) and Achilles tendon, were analyzed. The data demonstrated that in order to reproduce the PCL behavior, the effective length of a BPTB graft (10 mm width) should be 34 mm, while the Achilles tendon graft (with a cross sectional area of 55 mm2) needs to be 48 mm in length. Longer grafts result in less resistance and shorter graft increased the graft resistance. An initial graft tension cannot help recreate the overall structural behavior of the PCL. These results suggest that graft length is an important surgical variable in PCL reconstruction. An optimal reconstruction of the PCL should reproduce the structural properties of the PCL by using a graft with an optimal length.
Skip Nav Destination
Article navigation
April 2003
Technical Papers
Determination of Optimal Graft Lengths for Posterior Cruciate Ligament Reconstruction—A Theoretical Analysis
Guoan Li,
Guoan Li
Orthopaedic Biomechanics Laboratory MGH/BIDMC and Harvard Medical School, Boston, MA 02214
Search for other works by this author on:
Louis DeFrate,
Louis DeFrate
Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139
Search for other works by this author on:
Jeremy Suggs,
Jeremy Suggs
Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139
Search for other works by this author on:
Thomas Gill
Thomas Gill
Orthopaedic Biomechanics Laboratory MGH/BIDMC and Harvard Medical School, Boston, MA 02215
Search for other works by this author on:
Guoan Li
Orthopaedic Biomechanics Laboratory MGH/BIDMC and Harvard Medical School, Boston, MA 02214
Louis DeFrate
Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139
Jeremy Suggs
Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139
Thomas Gill
Orthopaedic Biomechanics Laboratory MGH/BIDMC and Harvard Medical School, Boston, MA 02215
Contributed by the Bioengineering Division for publication in the JOURNAL OF BIOMECHANICAL ENGINEERING. Manuscript received May, 2002; revised manuscript received Nov. 2002. Associate Editor: L. J. Soslowsky.
J Biomech Eng. Apr 2003, 125(2): 295-299 (5 pages)
Published Online: April 9, 2003
Article history
Received:
May 1, 2002
Revised:
November 1, 2002
Online:
April 9, 2003
Citation
Li, G., DeFrate , L., Suggs, J., and Gill, T. (April 9, 2003). "Determination of Optimal Graft Lengths for Posterior Cruciate Ligament Reconstruction—A Theoretical Analysis ." ASME. J Biomech Eng. April 2003; 125(2): 295–299. https://doi.org/10.1115/1.1554409
Download citation file:
Get Email Alerts
Effect of Collagen Fiber Tortuosity Distribution on the Mechanical Response of Arterial Tissues
J Biomech Eng (February 2025)
Related Articles
Tendon to Bone Healing: Differences in Biomechanical, Structural, and Compositional Properties Due to a Range of Activity Levels
J Biomech Eng (February,2003)
Roentgen Stereophotogrammetric Analysis Methods for Determining Ten Causes of Lengthening of a Soft-Tissue Anterior Cruciate Ligament Graft Construct
J Biomech Eng (August,2008)
Development and Validation of a Three-Dimensional Finite Element Model of the Face
J Biomech Eng (April,2009)
Related Chapters
Novel and Efficient Mathematical and Computational Methods for the Analysis and Architecting of Ultralight Cellular Materials and their Macrostructural Responses
Advances in Computers and Information in Engineering Research, Volume 2
mDFA Human Empirical Results
Modified Detrended Fluctuation Analysis (mDFA)
Mechanical Effect Analysis of Interaction between Tunnel Support Structure and Surrounding Rock
Geological Engineering: Proceedings of the 1 st International Conference (ICGE 2007)