In this paper, a new technique, using a tiny thermistor with 0.3~0.5mm in diameter to determine thermal conductivity of biomaterials in wide temperature range, has been developed. Based on steady spherical heat transfer in an infinite homogeneous medium, thermal conductivity of the measured medium can be determined by power applied and temperature rise of the thermistor. Compared with recommended values, maximum measurement errors of standard samples, aqueous glycol and CaCl2 solutions, water and ice, are 5.1% in temperature range 233~313K. The thermal conductivities of rabbit’s liver, kidney, heart and carotid artery in temperature range 233~293K are determined. Error caused by measurement parameters, effects of the finite scale of the measured medium and the decoupler between the thermistor and the medium are analyzed.
Skip Nav Destination
ASME 2002 International Mechanical Engineering Congress and Exposition
November 17–22, 2002
New Orleans, Louisiana, USA
Conference Sponsors:
- Heat Transfer Division
ISBN:
0-7918-3639-8
PROCEEDINGS PAPER
A Tiny Detector Made of a Self-Heated Thermistor for Determining Thermal Conductivity of Biomaterials in Temperature Range 233~313K
H. F. Zhang,
H. F. Zhang
University of Science and Technology of China, Hefei, China
Search for other works by this author on:
S. X. Cheng,
S. X. Cheng
University of Science and Technology of China, Hefei, China
Search for other works by this author on:
L. Q. He,
L. Q. He
University of Science and Technology of China, Hefei, China
Search for other works by this author on:
A. L. Zhang,
A. L. Zhang
University of Science and Technology of China, Hefei, China
Search for other works by this author on:
Y. Zheng,
Y. Zheng
University of Science and Technology of China, Hefei, China
Search for other works by this author on:
D. Y. Gao
D. Y. Gao
University of Science and Technology of China, Hefei, China
Search for other works by this author on:
H. F. Zhang
University of Science and Technology of China, Hefei, China
S. X. Cheng
University of Science and Technology of China, Hefei, China
L. Q. He
University of Science and Technology of China, Hefei, China
A. L. Zhang
University of Science and Technology of China, Hefei, China
Y. Zheng
University of Science and Technology of China, Hefei, China
D. Y. Gao
University of Science and Technology of China, Hefei, China
Paper No:
IMECE2002-33683, pp. 17-21; 5 pages
Published Online:
June 3, 2008
Citation
Zhang, HF, Cheng, SX, He, LQ, Zhang, AL, Zheng, Y, & Gao, DY. "A Tiny Detector Made of a Self-Heated Thermistor for Determining Thermal Conductivity of Biomaterials in Temperature Range 233~313K." Proceedings of the ASME 2002 International Mechanical Engineering Congress and Exposition. Advances in Heat and Mass Transfer in Biotechnology. New Orleans, Louisiana, USA. November 17–22, 2002. pp. 17-21. ASME. https://doi.org/10.1115/IMECE2002-33683
Download citation file:
3
Views
0
Citations
Related Proceedings Papers
Related Articles
Noninvasive Blood Perfusion Measurements of an Isolated Rat Liver and an Anesthetized Rat Kidney
J Biomech Eng (December,2008)
Thermal Processing of Biological Tissue at High Temperatures: Impact of Protein Denaturation and Water Loss on the Thermal Properties of Human and Porcine Liver in the Range 25–80 °C
J. Heat Transfer (June,2013)
A Probe Technique for Determining the Thermal Conductivity of Tissue
J. Heat Transfer (May,1972)
Related Chapters
Case Study 10: Data Reconciliation
Engineering Optimization: Applications, Methods, and Analysis
Summary
Heat Transfer & Hydraulic Resistance at Supercritical Pressures in Power Engineering Applications
The Latest Hot CD
Hot Air Rises and Heat Sinks: Everything You Know about Cooling Electronics Is Wrong